16.2: COD Interpretation
Environment โ Environment โ Environmental Engineering Numericals โ Environmental Engineering Numericals โ Environmental Calculations | Author: admin | Sep 14, 2026
1. CONCEPTUAL FRAMEWORK & CHEMICAL OXIDATION
A. Definition & Core Principle
Chemical Oxygen Demand (COD)
Chemical Oxygen Demand (COD) is the amount of oxygen required to chemically oxidize oxidizable substances present in a water or wastewater sample.
This includes:
Biodegradable organic compounds
Non-biodegradable or refractory organic compounds
Some oxidizable inorganic substances
BOD vs COD
BOD measures oxygen consumed through biological oxidation.
COD measures oxygen demand through chemical oxidation using a strong oxidizing agent.
Therefore, COD is generally greater than BOD for the same wastewater.
Oxygen Demand Hierarchy
A useful conceptual relationship is:
ThOD โฅ COD โฅ BODแตค โฅ BODโ
Where:
ThOD = Theoretical Oxygen Demand
COD = Chemical Oxygen Demand
BODแตค = Ultimate BOD
BODโ = 5-day BOD
These relationships are useful as a general conceptual framework, although the exact relationship depends on the wastewater composition and analytical method.
BOD vs COD โ Test Duration
BODโ
Biological test
5 days
20ยฐC
Requires microorganisms
Measures oxygen consumed biologically
COD
Chemical test
Usually completed in about 2โ3 hours using the conventional dichromate digestion method
Uses strong chemical oxidizing conditions
Much faster than BODโ
Engineering Significance
Because COD can be determined much faster than BODโ , it is widely used for:
Industrial wastewater monitoring
Treatment-plant process control
Rapid assessment of organic pollution load
OXYGEN DEMAND SPECTRUM
OXYGEN DEMAND
โ
โผ
COD
โ
โโโโโโโโโโโโโโโโโโโดโโโโโโโโโโโโโโโโโโ
โ โ
โผ โผ
Biodegradable Refractory /
fraction poorly biodegradable
โ โ
โผ โผ
BODแตค Complex organics
โ
โผ
BODโ
Examples of Refractory Organic Matter
Depending on the wastewater source, refractory compounds may include:
Synthetic dyes
Lignin
Resins
Certain pesticides
Complex industrial solvents
Other persistent organic compounds
B. LABORATORY COD DIGESTION CHEMISTRY
The conventional COD test uses a strong oxidizing system under acidic and elevated-temperature conditions.
1. Primary Oxidizing Agent
Potassium dichromate โ KโCrโOโ
It is used in the presence of concentrated sulphuric acid.
The conventional digestion is carried out at approximately:
150ยฐC for about 2 hours
2. Catalyst
Silver sulphate โ AgโSOโ
Silver sulphate acts as a catalyst and improves oxidation of certain organic compounds, particularly some straight-chain aliphatic compounds.
3. Chloride Interference Control
Mercuric sulphate โ HgSOโ
Chloride ions can interfere with the dichromate COD determination.
HgSOโ is used to complex chloride ions and reduce this interference.
Without adequate chloride masking:
Chloride interference โ โ measured COD may be falsely high
4. Back-Titration
After digestion, the remaining unreacted dichromate is determined by titration using:
Ferrous Ammonium Sulphate (FAS)
with Ferroin indicator.
Basic Principle
Dichromate added initially
โ
Some dichromate oxidizes wastewater
โ
Remaining dichromate
โ
Back-titrated using FAS
โ
Difference between blank and sample
โ
COD
The dichromate reduction can be represented conceptually as:
CrโOโยฒโป โ Crยณโบ
The dichromate ion is reduced from hexavalent chromium to trivalent chromium.
2. BOD/COD RATIO & WASTEWATER TREATABILITY
BOD/COD Ratio
The ratio:
BODโ / COD
is commonly used as an indicator of the biodegradability of wastewater.
It helps engineers assess whether biological treatment is likely to be effective.
Basic Logic
BOD/COD ratio
โ
โโโ High ratio
โ โ
โ Large biodegradable fraction
โ โ
โ Biological treatment more suitable
โ
โโโ Low ratio
โ
Large refractory fraction
โ
Biological treatment may be less effective
BOD/COD TREATABILITY MATRIX
BOD/COD RATIO
0.0 โโโโโโโโโโโโโโโ 0.2 โโโโโโโโโโโโโโโโโ 0.5 โโโโโโโโโโโโโโโโโ 1.0
โ โ โ
โผ โผ โผ
Very Low Moderate High
Biodegradability Biodegradability Biodegradability
Refractory / Biological treatment Conventional
toxic compounds may require biological treatment
pre-treatment
General Engineering Interpretation
| BODโ /COD Ratio | COD/BODโ Ratio | General Interpretation | Possible Treatment Approach |
|---|---|---|---|
| โฅ 0.5 | โค 2.0 | Highly biodegradable | Biological treatment such as ASP or trickling filter |
| 0.2โ0.5 | 2.0โ5.0 | Moderately biodegradable | Biological treatment with suitable acclimatization and/or physico-chemical pre-treatment |
| < 0.2 | > 5.0 | Low biodegradability / potentially refractory | Pre-treatment such as oxidation, adsorption or other suitable physico-chemical processes may be required |
Important
These ratio ranges are engineering rules of thumb, not universal regulatory limits.
Treatment selection must also consider:
Toxicity
Specific contaminants
Nutrient concentrations
pH
Salinity
Temperature
Hydraulic loading
Existing microbial population
Required effluent quality
Refractory Organic Matter
Industries such as:
Tanneries
Paper and pulp mills
Textile dyeing units
Chemical industries
Refineries
may generate wastewater containing complex organic compounds.
Such wastewater can have a low BODโ /COD ratio.
For example:
BODโ /COD < 0.2
suggests that only a relatively small fraction of the measured COD is readily biodegradable.
In such cases, direct biological treatment may be inadequate and suitable pre-treatment may be required.
3. CORE MATHEMATICAL FORMULAS FOR COD
COD CALCULATIONS
โ
โโโโโโโโโโโโโโโโโโโโโโโผโโโโโโโโโโโโโโโโโโโโโโ
โ โ โ
โผ โผ โผ
COD TITRATION ThOD TREATABILITY
โ โ โ
โผ โผ โผ
COD = (VbโVs)Nร8000/Vsample Stoichiometry BODโ
/COD
โ
โผ
Treatment selection
FORMULA 1 โ COD FROM FAS TITRATION
The conventional dichromate COD method can be calculated using:
COD (mg/L) = [(Vb โ Vs) ร N_FAS ร 8000] / Vsample
Where:
Vb = FAS volume used for blank titration, mL
Vs = FAS volume used for sample titration, mL
N_FAS = Normality of FAS solution
Vsample = Wastewater sample volume, mL
8000 = conversion factor based on the equivalent weight of oxygen
Why 8000?
Equivalent weight of oxygen:
32 / 4 = 8 g/eq
Converting grams to milligrams:
8 ร 1000 = 8000 mg/eq
Therefore:
8000 = mg Oโ per equivalent
FORMULA 2 โ THEORETICAL OXYGEN DEMAND (ThOD)
For a compound represented by:
CโHโOแตฆN๐
complete oxidation can be represented as:
CโHโOแตฆN๐ + (n + a/4 โ b/2 โ 3c/4)Oโ โ nCOโ + [(a โ 3c)/2]HโO + cNHโ
The oxygen requirement is:
Oโ moles required = n + a/4 โ b/2 โ 3c/4
Therefore:
ThOD (g Oโ/g compound) = [Oโ moles required ร 32] / Molar Mass
Where:
32 = molecular mass of Oโ in g/mol
FORMULA 3 โ BIODEGRADABILITY INDEX
Biodegradability Index
BI = BODโ / COD
Interpretation
Higher BI:
More biodegradable material โ Biological treatment more feasible
Lower BI:
More refractory material โ Biological treatment becomes more difficult
REFRACTORY COD
The simplified calculation used in this chapter is:
Refractory COD = Total COD โ Ultimate BOD
Therefore:
CODrefractory = CODtotal โ BODแตค
Where:
BODแตค = BODโ / (1 โ eโปโตแต)
This calculation assumes that the BOD kinetics can be represented by the first-order model used in Unit 16.1.
FORMULA 4 โ COD REMOVAL EFFICIENCY
% COD Removal = [(CODin โ CODout) / CODin] ร 100
Where:
CODin = COD entering treatment
CODout = COD leaving treatment
FORMULA 5 โ DAILY COD MASS LOAD
COD Load (kg/day) = Q ร COD ร 10โปยณ
Where:
Q = wastewater flow, mยณ/day
COD = concentration, mg/L
4. SOLVED NUMERICAL PROBLEMS
PROBLEM 1 โ LABORATORY COD DETERMINATION BY TITRATION
Question
A 50 mL industrial wastewater sample is digested with potassium dichromate in acidic medium.
After digestion:
FAS used for sample titration = 14.2 mL
FAS used for blank titration = 26.8 mL
FAS normality = 0.10 N
Wastewater sample volume = 50 mL
Calculate the COD.
Solution
Step 1 โ Identify the values
Vb = 26.8 mL
Vs = 14.2 mL
N_FAS = 0.10 N
Vsample = 50 mL
Step 2 โ Apply COD formula
COD = [(Vb โ Vs) ร N_FAS ร 8000] / Vsample
Substitute:
COD = [(26.8 โ 14.2) ร 0.10 ร 8000] / 50
First:
26.8 โ 14.2 = 12.6 mL
Therefore:
COD = (12.6 ร 0.10 ร 8000) / 50
COD = 10,080 / 50
COD = 201.6 mg/L
Answer
COD = 201.6 mg/L
PROBLEM 2 โ ThOD OF GLUCOSE & ETHANOL
Question
Calculate the theoretical oxygen demand of a solution containing:
Glucose = 300 mg/L
Ethanol = 100 mg/L
Calculate the total ThOD.
PART A โ GLUCOSE
Glucose formula:
CโHโโOโ
Oxidation Reaction
CโHโโOโ + 6Oโ โ 6COโ + 6HโO
Therefore:
1 mole glucose requires 6 moles Oโ
Step 1 โ Molecular Mass of Glucose
Molar mass = (6 ร 12) + (12 ร 1) + (6 ร 16)
= 72 + 12 + 96
= 180 g/mol
Step 2 โ Oxygen Required
6 ร 32 = 192 g Oโ/mol glucose
Therefore:
ThOD = 192 / 180
ThOD = 1.067 g Oโ/g glucose
Step 3 โ Oxygen Demand for 300 mg/L
ThOD = 300 ร 1.067
ThOD = 320.1 mg/L
PART B โ ETHANOL
Ethanol formula:
CโHโ OH
Equivalent molecular formula:
CโHโO
Oxidation Reaction
CโHโO + 3Oโ โ 2COโ + 3HโO
Therefore:
1 mole ethanol requires 3 moles Oโ
Step 1 โ Molecular Mass
Molar mass = (2 ร 12) + (6 ร 1) + (1 ร 16)
= 24 + 6 + 16
= 46 g/mol
Step 2 โ Oxygen Required
3 ร 32 = 96 g Oโ/mol ethanol
Therefore:
ThOD = 96 / 46
ThOD = 2.087 g Oโ/g ethanol
Step 3 โ Oxygen Demand for 100 mg/L
ThOD = 100 ร 2.087
ThOD = 208.7 mg/L
PART C โ TOTAL ThOD
Total ThOD = ThODglucose + ThODethanol
= 320.1 + 208.7
= 528.8 mg/L
Answer
Total ThOD = 528.8 mg/L
PROBLEM 3 โ BOD/COD RATIO & TREATABILITY
Question
A pharmaceutical industry generates wastewater having:
COD = 1,200 mg/L
BODโ = 180 mg/L
At 20ยฐC:
k = 0.23 dayโปยน
Calculate:
BODโ /COD ratio
Treatability status
Ultimate BOD
Refractory COD
Step 1 โ Calculate BODโ /COD
BI = BODโ / COD
BI = 180 / 1200
BI = 0.15
Interpretation
BI = 0.15 < 0.20
Therefore, the wastewater has low biodegradability according to the rule-of-thumb classification used here.
Step 2 โ Treatment Implication
A low BODโ /COD ratio suggests that a large portion of the COD may be refractory or poorly biodegradable.
Therefore:
Direct biological treatment may be inadequate.
Possible treatment strategy:
Industrial Wastewater
โ
Physico-Chemical / Oxidative Pre-treatment
โ
Breakdown of refractory compounds
โ
Biological Treatment
โ
Final Treatment / Polishing
โ
Discharge or Reuse
Possible pre-treatment processes include:
Fenton oxidation
Ozonation
Other Advanced Oxidation Processes
Adsorption
Appropriate physico-chemical treatment
The actual treatment train must be selected based on the specific contaminants and treatability studies.
Step 3 โ Calculate Ultimate BOD
Use:
BODโ = Lโ(1 โ eโปโตแต)
Given:
BODโ = 180 mg/L
k = 0.23 dayโปยน
Therefore:
180 = Lโ(1 โ eโปโฝโฐยทยฒยณ ร โตโพ)
180 = Lโ(1 โ eโปยนยทยนโต)
Since:
eโปยนยทยนโต โ 0.3166
Therefore:
180 = Lโ ร 0.6834
Hence:
Lโ = 180 / 0.6834
Lโ โ 263.4 mg/L
Step 4 โ Calculate Refractory COD
Using the simplified relationship:
CODrefractory = CODtotal โ BODแตค
Therefore:
CODrefractory = 1200 โ 263.4
CODrefractory = 936.6 mg/L
Percentage of Total COD
Refractory fraction = 936.6 / 1200 ร 100
โ 78.05%
Answer
BODโ /COD = 0.15
Biodegradability = Low
Ultimate BOD โ 263.4 mg/L
Refractory COD โ 936.6 mg/L
Refractory fraction โ 78.1%
PROBLEM 4 โ INDUSTRIAL COD MASS BALANCE
Question
A textile dyeing facility generates:
Flow = 1,500 mยณ/day
Influent COD = 850 mg/L
Treatment system:
Stage 1
Chemical coagulation removes 40% COD.
Stage 2
Biological aerated filter removes 70% of the remaining COD.
Calculate:
Final effluent COD
Daily COD discharged
Step 1 โ Stage 1 COD
40% is removed.
Therefore, 60% remains.
CODstage 1 = 850 ร (1 โ 0.40)
CODstage 1 = 850 ร 0.60
CODstage 1 = 510 mg/L
Step 2 โ Stage 2 COD
The biological filter removes 70% of the remaining COD.
Therefore, 30% remains.
CODfinal = 510 ร (1 โ 0.70)
CODfinal = 510 ร 0.30
CODfinal = 153 mg/L
Step 3 โ Daily COD Mass Discharged
Use:
COD Load = Q ร COD ร 10โปยณ
Therefore:
Load = 1500 ร 153 ร 10โปยณ
Load = 229.5 kg/day
Answer
Final COD = 153 mg/L
Daily COD discharged = 229.5 kg/day
5. FORMULA SUMMARY & QUICK REFERENCE SHEET
| Parameter / Metric | Formula | Key Interpretation |
|---|---|---|
| Laboratory COD Titration | COD = [(Vb โ Vs) ร N_FAS ร 8000] / Vsample | COD in mg/L |
| Theoretical Oxygen Demand | ThOD = (Moles Oโ required ร 32) / Molar Mass | Stoichiometric oxygen demand |
| Biodegradability Index | BI = BODโ / COD | Higher ratio โ greater biodegradability |
| Refractory COD | CODrefractory = CODtotal โ BODแตค | Simplified estimate of non-biodegradable COD |
| Ultimate BOD | BODแตค = BODโ / (1 โ eโปโตแต) | Based on first-order BOD kinetics |
| COD Removal | % Removal = [(CODin โ CODout) / CODin] ร 100 | Percentage COD reduction |
| Daily COD Load | Load = Q ร COD ร 10โปยณ | Q in mยณ/day; COD in mg/L |
6. EXAM-ORIENTED COD LOGIC
If FAS titration values are given
Use:
COD = [(Vb โ Vs) ร N ร 8000] / Vsample
Remember:
Blank โ Sample
not:
Sample โ Blank
If chemical formula is given
Calculate:
Molecular mass
Moles of Oโ required
Oxygen mass required
ThOD
If BODโ and COD are given
Calculate:
BODโ /COD
Then interpret biodegradability.
If BODโ and k are given
First calculate ultimate BOD:
BODแตค = BODโ / (1 โ eโปโตแต)
Then, if required:
Refractory COD = Total COD โ BODแตค
If treatment removal percentages are given
Apply each removal percentage sequentially.
Example:
COD = 1000 mg/L
40% removal
โ
600 mg/L remains
70% removal of remaining COD
โ
180 mg/L remains
Never add:
40% + 70% = 110%
Instead:
1000 ร 0.60 ร 0.30 = 180 mg/L
If flow and COD are given
Use:
COD Load = Q ร COD ร 10โปยณ kg/day
7. BOD vs COD โ FINAL COMPARISON
| Feature | BOD | COD |
|---|---|---|
| Full form | Biological Oxygen Demand | Chemical Oxygen Demand |
| Principle | Biological oxidation | Chemical oxidation |
| Main agent | Microorganisms | Chemical oxidant |
| Typical test time | 5 days | About 2โ3 hours |
| Measures | Biodegradable oxygen demand | Chemically oxidizable oxygen demand |
| Speed | Slow | Fast |
| Operational monitoring | Less suitable for immediate control | Very useful |
| General magnitude | Lower | Usually higher |
| Main use | Biodegradability / biological pollution assessment | Rapid organic load assessment |
8. BOD/COD TREATABILITY MEMORY
BODโ
/ COD
โ
โโโโโโโโโโโโโโโผโโโโโโโโโโโโโโ
โ โ โ
โผ โผ โผ
< 0.2 0.2โ0.5 โฅ 0.5
โ โ โ
โผ โผ โผ
Low biological Moderate High
treatability biological biological
treatability treatability
โ โ โ
โผ โผ โผ
Pre-treatment Combined / Conventional
often required adapted biological
treatment treatment
Easy Memory
High BOD/COD โ Biological treatment is easier
Low BOD/COD โ Refractory fraction is higher โ Pre-treatment may be needed
9. MUST REMEMBER
COD
Chemical Oxygen Demand
Oxygen required to chemically oxidize oxidizable substances.
Main COD Oxidant
Potassium dichromate โ KโCrโOโ
Acid Medium
Sulphuric acid โ HโSOโ
Catalyst
Silver sulphate โ AgโSOโ
Chloride Interference Control
Mercuric sulphate โ HgSOโ
Back-Titration
Ferrous Ammonium Sulphate (FAS)
Indicator
Ferroin
COD Formula
COD = [(Vb โ Vs) ร N ร 8000] / Vsample
Biodegradability Index
BI = BODโ / COD
ThOD
Based on the stoichiometric oxygen requirement for complete oxidation.
Mass Load
COD Load = Q ร COD ร 10โปยณ kg/day
10. ONE-MINUTE MEMORY MAP
COD
โ
โโโโโโโโโโโโโโโโโโผโโโโโโโโโโโโโโโโโ
โ โ โ
โผ โผ โผ
LAB TEST TREATABILITY LOAD
โ โ โ
โผ โผ โผ
KโCrโOโ + HโSOโ BODโ
/ COD Q ร COD ร 10โปยณ
โ โ
โผ โผ
AgโSOโ + HgSOโ High โ biological
โ Low โ pre-treatment
โผ
Digestion
โ
โผ
FAS titration
โ
โผ
COD
11. QUICK REVISION QUESTIONS
What is COD?
What is the main difference between BOD and COD?
Why is COD determination faster than BODโ ?
What is the main oxidizing agent used in the conventional COD test?
What is the role of sulphuric acid?
What is the role of silver sulphate?
Why is mercuric sulphate used?
What is FAS?
Why is a blank titration required?
Why is the blank FAS volume greater than the sample FAS volume?
What does the BODโ /COD ratio indicate?
What does a very low BODโ /COD ratio indicate?
What is ThOD?
How is ThOD calculated from a chemical formula?
What is refractory COD?
How is daily COD mass load calculated?
Why should treatment removal percentages be applied sequentially?
What happens to biological treatability when the BODโ /COD ratio decreases?
CORE FORMULAS
1. COD = [(Vb โ Vs) ร N_FAS ร 8000] / Vsample
2. ThOD = (Moles Oโ required ร 32) / Molar Mass
3. BI = BODโ / COD
4. BODแตค = BODโ / (1 โ eโปโตแต)
5. CODrefractory = CODtotal โ BODแตค
6. % COD Removal = [(CODin โ CODout) / CODin] ร 100
7. COD Load = Q ร COD ร 10โปยณ kg/day
These formulas cover the principal COD calculation patterns required for this unit.