16.1: BOD-Based Calculations
Environment β Environment β Environmental Engineering Numericals β Environmental Engineering Numericals β Environmental Calculations | Author: admin | Sep 14, 2026
1. CONCEPTUAL FRAMEWORK & WATER QUALITY THRESHOLDS
A. Definition & Standard Laboratory Test β BODβ
Biological Oxygen Demand (BOD)
Biological Oxygen Demand (BOD) is the amount of dissolved oxygen (DO) required by aerobic microorganisms to biologically decompose biodegradable organic matter present in water or wastewater.
Standard BODβ Test
The complete decomposition of organic matter may take several weeks. Therefore, the standard laboratory test measures oxygen consumption over:
5 days
20Β°C
In the dark
This is called BODβ .
The test is kept in the dark to prevent algae from producing oxygen through photosynthesis, which would interfere with the measurement.
Remember:
BODβ = oxygen consumed biologically during 5 days at 20Β°C.
B. Dissolved Oxygen (DO) & Anoxic Conditions
When microorganisms decompose organic matter, they consume dissolved oxygen from the water.
Therefore:
More biodegradable organic matter β Higher BOD β Greater DO depletion
A high BOD generally indicates a greater oxygen demand on the receiving water body.
Important DO Levels
| DO Concentration | General Condition | Environmental Meaning |
|---|---|---|
| β₯ 8.0 mg/L | Clean / well-oxygenated | Healthy aquatic conditions |
| < 8.0 mg/L | Reduced DO | Increasing pollution stress |
| < 4.0 mg/L | Highly polluted | Severe aquatic stress; fish kills may occur |
| < 1.5 mg/L | Critical oxygen depletion | Anaerobic conditions may develop |
At very low DO levels, aerobic biological activity becomes severely limited and anaerobic decomposition can become dominant.
Anaerobic decomposition may produce compounds such as:
Hydrogen sulfide (HβS)
Ammonia (NHβ)
Methane (CHβ)
DO & Ecological Status
DISSOLVED OXYGEN (DO) & ECOLOGICAL STATUS
0 βββββββββ 1.5 βββββββββββββ 4.0 βββββββββββββ 8.0 βββββββββββββ 14.0 mg/L
β β β β
βΌ βΌ βΌ βΌ
Very Low Critical Highly Well
DO Oxygen Polluted Oxygenated
Depletion
Anaerobic Severe oxygen Severe aquatic Healthy
conditions stress stress aquatic life
Possible formation of:
HβS, NHβ, CHβ
Important: DO concentration alone should not be treated as a universal pollution-classification scale because natural DO varies with temperature, salinity, altitude, and water-body characteristics. For numerical problems, use the values specifically given in the question.
C. BODβ Water Quality Rating Scale
| BODβ Concentration | General Classification | Meaning |
|---|---|---|
| 1β2 mg/L | Very Good | Very little biodegradable organic matter |
| 3β5 mg/L | Fair | Moderately clean water |
| 6β9 mg/L | Poor | Noticeable organic pollution |
| β₯ 10 mg/L | Very Poor | High organic pollution load |
Exam logic:
Higher BOD β More biodegradable organic matter β More oxygen consumed β Greater pollution potential.
D. Effluent Standards & BOD vs COD
BOD Discharge Limit
For numerical problems, a commonly used reference value for treated wastewater discharged to surface waters is:
BOD β€ 30 mg/L
However, actual regulatory limits depend on the applicable discharge category, location, consent conditions, and current standards.
Always use the standard specified in the question.
BOD vs COD
BOD
Measures oxygen required for biological oxidation of biodegradable organic matter.
COD
Measures oxygen required for chemical oxidation of oxidizable substances, including many compounds that may not be readily biodegradable.
Therefore, in most wastewater samples:
COD > BOD
The BOD/COD ratio is also useful for assessing wastewater biodegradability.
2. CORE MATHEMATICAL FORMULAS FOR BOD CALCULATIONS
BOD CALCULATION FORMULAS
BOD
β
ββββββββββββββββββββββββΌβββββββββββββββββββββββ
β β β
βΌ βΌ βΌ
Dilution Method Reaction Kinetics Temperature Correction
β β β
βΌ βΌ βΌ
BODβ
= (DOα΅’ - DOπ) Γ DF BODβ = Lβ(1-eβ»α΅α΅) kT = kββ Γ ΞΈ^(T-20)
β
βΌ
Removal Efficiency
β
βΌ
% Removal = [(BODin-BODout)/BODin] Γ 100
FORMULA 1 β BOD DETERMINATION BY DILUTION METHOD
When raw wastewater is highly polluted, its dissolved oxygen may be completely consumed before 5 days.
Therefore, the wastewater is diluted with oxygen-saturated dilution water.
Formula
BODβ = (DOα΅’ β DOπ) Γ Dilution Factor
Where:
DOα΅’ = Initial dissolved oxygen of diluted sample, mg/L
DOπ = Final dissolved oxygen after 5 days, mg/L
Dilution Factor
DF = Vtotal / Vsample
Therefore:
DF = (Vsample + Vdilution water) / Vsample
If P is the fraction of wastewater in the total mixture:
P = Vsample / Vtotal
Then:
DF = 1 / P
Basic Logic
More dilution
β
More dilution factor
β
Measured DO depletion is multiplied
β
Original wastewater BOD is obtained
FORMULA 2 β FIRST-ORDER BOD REACTION KINETICS
The oxidation of biodegradable organic matter is commonly represented using first-order kinetics.
The rate of oxidation is proportional to the amount of biodegradable organic matter remaining.
Base-e Form
BODβ = Lβ(1 β eβ»α΅α΅)
Where:
BODβ = BOD exerted at time t, mg/L
Lβ = Ultimate Carbonaceous BOD, mg/L
k = First-order reaction rate constant, dayβ»ΒΉ
t = Time, days
The remaining organic matter is:
Lβ = Lβeβ»α΅α΅
Therefore:
BODβ = Lβ β Lβ
Base-10 Form
The same relationship can also be written as:
BODβ = Lβ(1 β 10β»α΄·α΅)
Where K is the base-10 reaction-rate constant.
The relationship between the two rate constants is:
k = 2.303K
Important
k β base-e constant
K β base-10 constant
Do not mix the two forms in a calculation.
FORMULA 3 β TEMPERATURE CORRECTION OF REACTION RATE CONSTANT
Microbial activity generally increases with temperature within the normal biological operating range.
Therefore, the reaction rate constant changes with temperature.
Formula
kT = kββ Γ ΞΈ^(T β 20)
Where:
kT = reaction rate constant at temperature T, dayβ»ΒΉ
kββ = reaction rate constant at 20Β°C, dayβ»ΒΉ
ΞΈ = temperature coefficient
T = temperature, Β°C
Commonly used values in this context:
ΞΈ = 1.047 for approximately 20β30Β°C
ΞΈ = 1.056 for approximately 15β20Β°C
Meaning
If temperature increases:
Temperature β β microbial activity β β k β β BOD is exerted faster
FORMULA 4 β BOD REMOVAL EFFICIENCY
Treatment plants reduce BOD through different treatment stages.
Formula
% BOD Removal = [(BODin β BODout) / BODin] Γ 100
Where:
BODin = BOD entering the treatment stage
BODout = BOD leaving the treatment stage
Typical Treatment Performance Used in Numerical Problems
Primary Treatment
Physical processes such as screening, grit removal and sedimentation can remove a portion of organic matter associated with suspended solids.
A typical numerical assumption may be:
BOD removal β 35%
Secondary Treatment
Biological treatment processes such as:
Activated Sludge Process
Trickling Filters
Oxidation Ponds
can achieve substantial BOD removal.
For numerical problems, the assumed removal efficiency should always be taken from the question.
FORMULA 5 β DAILY BOD MASS LOADING
Daily BOD load is the total mass of BOD entering or leaving a system per day.
Formula
BOD Load (kg/day) = Q Γ BOD Γ 10β»Β³
Where:
Q = wastewater flow, mΒ³/day
BOD = concentration, mg/L
Why 10β»Β³?
Because:
1 mΒ³ = 1,000 L
and:
1,000 mg = 0.001 kg
Therefore:
1 mg/L Γ 1 mΒ³ = 0.001 kg
Hence:
Load = Q Γ concentration Γ 10β»Β³
POPULATION EQUIVALENT (PE)
Population Equivalent expresses an industrial pollution load as the equivalent pollution load produced by a population.
Formula
PE = Total Industrial BOD Load (g/day) / Per-Capita BOD Load (g/person/day)
For the numerical problems in this chapter:
Per-capita domestic BOD contribution = 54 g/person/day
or:
0.054 kg/person/day
Meaning
If an industry produces 2,700 kg BOD/day:
PE = 2,700 / 0.054 = 50,000 persons
Therefore, its BOD load is equivalent to the domestic BOD load of approximately 50,000 people.
3. SOLVED NUMERICAL PROBLEMS
PROBLEM 1 β BODβ BY DILUTION METHOD
Question
A 10 mL sample of raw domestic sewage is diluted to 300 mL in a standard BOD bottle using aerated water.
Initial DO = 9.0 mg/L
Final DO after 5 days = 3.0 mg/L
Calculate the BODβ of the raw sewage.
Solution
Step 1 β Calculate Dilution Factor
DF = Vtotal / Vsample
DF = 300 / 10
DF = 30
Step 2 β Calculate BODβ
BODβ = (DOα΅’ β DOπ) Γ DF
BODβ = (9.0 β 3.0) Γ 30
BODβ = 6.0 Γ 30
BODβ = 180 mg/L
Answer
BODβ = 180 mg/L
PROBLEM 2 β FIRST-ORDER KINETICS & ULTIMATE BOD
Question
The 5-day BOD of wastewater at 20Β°C is 200 mg/L.
Given:
kββ = 0.23 dayβ»ΒΉ
Calculate:
Ultimate Carbonaceous BOD (Lβ)
3-day BOD (BODβ)
Solution
Step 1 β Calculate Ultimate BOD
Use:
BODβ = Lβ(1 β eβ»α΅α΅)
At t = 5 days:
200 = Lβ(1 β eβ»β½β°Β·Β²Β³ Γ β΅βΎ)
200 = Lβ(1 β eβ»ΒΉΒ·ΒΉβ΅)
Since:
eβ»ΒΉΒ·ΒΉβ΅ β 0.3166
Therefore:
200 = Lβ(1 β 0.3166)
200 = Lβ Γ 0.6834
Therefore:
Lβ = 200 / 0.6834
Lβ β 292.65 mg/L
Step 2 β Calculate BODβ
Use:
BODβ = Lβ(1 β eβ»α΅α΅)
BODβ = 292.65 Γ (1 β eβ»β½β°Β·Β²Β³ Γ Β³βΎ)
BODβ = 292.65 Γ (1 β eβ»β°Β·βΆβΉ)
Since:
eβ»β°Β·βΆβΉ β 0.5016
Therefore:
BODβ = 292.65 Γ (1 β 0.5016)
BODβ = 292.65 Γ 0.4984
BODβ β 145.86 mg/L
Answer
Ultimate BOD, Lβ β 292.65 mg/L
BODβ β 145.86 mg/L
PROBLEM 3 β TEMPERATURE CORRECTION
Question
A wastewater sample has a base-e reaction rate constant:
kββ = 0.10 dayβ»ΒΉ at 20Β°C
Determine the reaction rate constant at 30Β°C.
Given:
ΞΈ = 1.047
Solution
Use:
kT = kββ Γ ΞΈ^(T β 20)
At 30Β°C:
kββ = 0.10 Γ 1.047^(30 β 20)
kββ = 0.10 Γ 1.047ΒΉβ°
Since:
1.047ΒΉβ° β 1.583
Therefore:
kββ = 0.10 Γ 1.583
kββ = 0.1583 dayβ»ΒΉ
Answer
kββ β 0.1583 dayβ»ΒΉ
The reaction rate constant increases by approximately 58.3%.
PROBLEM 4 β MULTI-STAGE SEWAGE TREATMENT
Question
Raw municipal sewage has:
BODβ = 250 mg/L
Primary sedimentation removes 35% of BOD.
Secondary activated sludge treatment removes 85% of the remaining BOD.
Calculate:
BOD after primary treatment
Final BOD after secondary treatment
Overall BOD removal efficiency
Step 1 β Primary Treatment
Remaining BOD:
BODprimary = 250 Γ (1 β 0.35)
BODprimary = 250 Γ 0.65
BODprimary = 162.5 mg/L
Step 2 β Secondary Treatment
Secondary treatment removes 85% of the remaining BOD.
Therefore, 15% remains:
BODfinal = 162.5 Γ (1 β 0.85)
BODfinal = 162.5 Γ 0.15
BODfinal = 24.375 mg/L
Approximately:
BODfinal = 24.38 mg/L
Step 3 β Compliance Check
Using the 30 mg/L reference value specified in this problem:
Final BOD = 24.38 mg/L
24.38 < 30 mg/L
Therefore, it satisfies the assumed discharge limit.
Step 4 β Overall Removal Efficiency
Overall removal = [(250 β 24.38) / 250] Γ 100
Overall removal β 90.25%
Answer
Primary effluent BOD = 162.5 mg/L
Final effluent BOD = 24.38 mg/L
Overall BOD removal = 90.25%
Important Concept
The removal efficiencies of successive treatment units are not simply added.
Wrong:
35% + 85% = 120%
Correct:
First remove 35%, then remove 85% of what remains.
PROBLEM 5 β DAILY BOD MASS LOAD & POPULATION EQUIVALENT
Question
An industrial food-processing plant discharges:
Flow = 2,000 mΒ³/day
BODβ = 1,350 mg/L
Calculate:
Daily BOD mass load
Population Equivalent (PE)
Given:
Per-capita BOD contribution = 54 g/person/day
Step 1 β Calculate Daily BOD Load
Use:
Load (kg/day) = Q Γ BOD Γ 10β»Β³
Therefore:
Load = 2,000 Γ 1,350 Γ 10β»Β³
Load = 2,700,000 Γ 10β»Β³
Load = 2,700 kg/day
Step 2 β Convert kg/day to g/day
2,700 kg/day Γ 1,000 g/kg
= 2,700,000 g/day
Step 3 β Calculate Population Equivalent
PE = Total BOD Load / Per-Capita BOD Load
PE = 2,700,000 / 54
PE = 50,000 persons
Answer
BOD load = 2,700 kg/day
Population Equivalent = 50,000 persons
Interpretation
The industry's BOD pollution load is approximately equivalent to the domestic BOD load generated by 50,000 people, using the assumed value of 54 g/person/day.
4. FORMULA SUMMARY & QUICK REFERENCE SHEET
| Formula | Equation | Key Variables |
|---|---|---|
| BOD Dilution Method | BODβ = (DOα΅’ β DOπ) Γ DF | DO in mg/L; DF = Vtotal / Vsample |
| Dilution Factor | DF = Vtotal / Vsample = 1/P | P = wastewater fraction |
| First-Order BOD | BODβ = Lβ(1 β eβ»α΅α΅) | Lβ in mg/L; k in dayβ»ΒΉ; t in days |
| Remaining Organic Matter | Lβ = Lβeβ»α΅α΅ | Lβ = organic matter remaining |
| Base Conversion | k = 2.303K | k = base-e; K = base-10 |
| Temperature Correction | kT = kββ Γ ΞΈ^(Tβ20) | T in Β°C |
| BOD Removal | % Removal = [(BODin β BODout) / BODin] Γ 100 | Concentrations in same units |
| Daily BOD Load | Load = Q Γ BOD Γ 10β»Β³ | Q in mΒ³/day; BOD in mg/L |
| Population Equivalent | PE = Load (g/day) / 54 | 54 g/person/day |
5. EXAM-ORIENTED CALCULATION LOGIC
A. If DO values and dilution are given
Use:
BODβ = DO depletion Γ Dilution Factor
B. If BODβ and k are given and Lβ is asked
Use:
BODβ = Lβ(1 β eβ»β΅α΅)
Rearrange:
Lβ = BODβ / (1 β eβ»β΅α΅)
C. If Lβ, k and time are given
Use:
BODβ = Lβ(1 β eβ»α΅α΅)
D. If temperature changes
Use:
kT = kββ Γ ΞΈ^(Tβ20)
E. If influent and effluent BOD are given
Use:
% Removal = [(BODin β BODout) / BODin] Γ 100
F. If flow and BOD concentration are given
Use:
BOD Load = Q Γ BOD Γ 10β»Β³ kg/day
G. If industrial BOD load and per-capita load are given
Use:
PE = Industrial BOD Load / Per-Capita BOD Load
6. MUST REMEMBER
BOD
BOD = Biological Oxygen Demand
Measures oxygen required for biological oxidation of biodegradable organic matter.
BODβ
5 days + 20Β°C + dark
Ultimate BOD
Lβ = total ultimate biodegradable oxygen demand represented by the kinetic model
First-Order Equation
BODβ = Lβ(1 β eβ»α΅α΅)
Base Conversion
k = 2.303K
Temperature Correction
kT = kββ Γ ΞΈ^(Tβ20)
BOD Load
Load = Q Γ BOD Γ 10β»Β³ kg/day
Population Equivalent
PE = Industrial BOD Load / Per-Capita BOD Load
Core Relationship
Organic pollution β β BOD β β DO depletion β β Aquatic stress β
BOD vs COD
Usually COD > BOD
7. ONE-MINUTE MEMORY MAP
BOD CALCULATIONS
β
ββββββββββββββββββββββββΌβββββββββββββββββββββββ
β β β
βΌ βΌ βΌ
MEASUREMENT KINETICS TREATMENT
β β β
βΌ βΌ βΌ
DO depletion BODβ = Lβ(1-eβ»α΅α΅) BOD removal %
β β β
βΌ βΌ βΌ
Dilution Factor Lβ, k, t BODin/BODout
β β
ββββββββββββββββ¬ββββββββ
βΌ
MASS LOADING
β
βΌ
Load = Q Γ BOD Γ 10β»Β³
β
βΌ
Population
Equivalent
β
βΌ
PE = Load / 54
8. QUICK REVISION QUESTIONS
What does BOD measure?
Why is the standard BOD test conducted for 5 days?
Why is the BOD test conducted at 20Β°C?
Why is the BOD bottle kept in the dark?
What happens to DO when BOD increases?
What is the dilution factor?
What is ultimate BOD, Lβ?
What is the first-order BOD equation?
What is the relationship between k and K?
How does temperature affect k?
What is BOD removal efficiency?
How do you calculate daily BOD load?
What is Population Equivalent?
Why is COD generally greater than BOD?
If treatment occurs in two stages, why can the removal percentages not simply be added?
CORE NUMERICAL FORMULAS
1. BODβ = (DOα΅’ β DOπ) Γ DF
2. DF = Vtotal / Vsample
3. BODβ = Lβ(1 β eβ»α΅α΅)
4. Lβ = Lβeβ»α΅α΅
5. k = 2.303K
6. kT = kββ Γ ΞΈ^(Tβ20)
7. % Removal = [(BODin β BODout) / BODin] Γ 100
8. BOD Load = Q Γ BOD Γ 10β»Β³ kg/day
9. PE = BOD Load (g/day) / 54
These nine formulas cover the main calculation patterns in this unit.